GENSET MODEL | Genset Specification | Engine Specification | Alternator Model | |||||||
KVA | Cons 100% (L/H) | dB(A) @7m | Tank (L) | Model | Cyl. | Gov. | Asp. | |||
ESP | PRP | |||||||||
KP-C94P | 100 | 94 | 22 | 70 | 300 | 6BT5.9-G1 | 6 | M | TC | KP274C |
KP-C100S | 100 | 94 | 22 | 70 | 300 | 6BT5.9-G1 | 6 | M | TC | KP274C |
Voltage regulation
Voltage regulation maintained within ±0.5% as follow:
● Power factor Between 0.8~1.0 lag
● From no load to full load, any steady load
● Speed droop variation under 4.5%
Frequency/Speed undulation
● Change load from 0-100%, Frequency/Speed Droop Ratio within 5%.
● Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%
Effect factor of telecom
● TIF( MA MG1-22) better than 50
● THF( BS EN60034) better than 2%
DIESEL GENERATOR SPECIFICATIONS
1. Powered by reliable engines
2. Branded alternator
3. Open type, silent type or super silent type generator
4. ISO, CE certified
GENERATOR SPECS:
Rated output: 2 to 2,000kW/2 to 2,500kVA
Rated voltage: L-N 110 to 277V, L-L 220 to 480V
Rated frequency: 50/60Hz
ENGINE:
Brands: Cummins, Perkins, Lovol, Deutz, Doosan, Mitsubishi, Kubota, Yanmar or other reliable Chines eengines such as Fawde and Laidong.
Cooling method: closed water-cooled or air-cooled
Starting method: electric start or recoil start
Rated speed: 1,500/1,800/3,000/3,600rpm
Noise level: 56 to 75dB, 7 meters away
ALTERNATOR:
Brands: Stamford, Leroy Somer, Mecc Alte and Keypower brushless alternator
Rated output: 8 to 2,000kW/10 to 2,500kVA
Rated voltage: L-N 110 to 277V, L-L 220 to 480V
Rated frequency: 50/60Hz
Phase: 3-phase, 4-wire or 1-phase, 2-wire
Connection: y or other type connection
Rated speed: 1,500/1,800rpm
Excitation: harmonic excitation or phase compound or brushless
Voltage regulation: AVR automatic
1.0% voltage regulation in static conditions (maximum)
Protection class: IP23
Control panel: Deepsea, ComAp, Keypower
THE PANEL IS PROVIDED WITH:
Standard engine instrumentation
Voltmeter with selector switch
Ammeter with selector switch
Frequency meter
Current transformers
MCB of suitable rating with overload and short-circuit protection
Optional with AMF control panel or with ATS (automatic transfer switch)
APPLICATIONS:
With advanced reasonable structure, high efficiency, low vibration and noise, smooth running, high reliability, easy handling, KEYPOWER generators are widely used in national defense, telecommunications, construction site, commercial buildings, industrial and mining sites, oil fields, roads, ports, villas, banks.